PR# 12126 Maximizing tool then closing it closes other tools and makes them unavailable

Problem Report Summary
Submitter: prestoat2000
Category: EiffelStudio
Priority: Medium
Date: 2007/02/24
Class: Bug
Severity: Serious
Number: 12126
Release: 6.0.66833
Confidential: No
Status: Closed
Responsible:
Environment: Mozilla/5.0 (X11; U; SunOS i86pc; en-US; rv:1.8.1) Gecko/20061228 Firefox/2.0 Solaris 10 on x64
Synopsis: Maximizing tool then closing it closes other tools and makes them unavailable

Description
Delete ~/.es directory.  Compile sample application.
Click Maximize button in Features tool, then click "X" to close it.
All other tools that were displayed before the Maximize have now disappeared
  as well.
Click on Clusters button or select View/Tools/Clusters (or Class or Metrics etc).
None of the tools that disappeared when the maximized Features tool was closed
can be brought back except by bringing back the Features tool (via the Features
button or via View/Tools/Features).  

I hope this is a bug because it is very confusing.
To Reproduce

										
Problem Report Interactions
From:larryl    Date:2007/02/28    Status: Closed    Download   
This is a bug. It's fixed after revision#66973, all other unmaximized tools will shown after you close a maximized tool.
Thanks for the report.